Home › Categories › Transformers & Switchgear

Transformers & Switchgear manufacturers in India

40 manufacturers of transformers & switchgear are listed on SourceLoka. 36 are listed as manufacturer exporters and 4 as merchant-cum-manufacturer exporters, which also trade goods they do not make.

Listed manufacturers
40
States
9
Cities
16

Listed manufacturers

40 manufacturers · best-documented first

Related categories

Explore similar products.

Typical transformers & switchgear products

Distribution transformersPower transformersMCC and PCC panelsControl panelsServo stabilisers

Typical products for this category, not a claim about any one company’s range.

What are transformers & switchgear?

Transformers change voltage levels in power distribution, and switchgear and panels protect, control and distribute that power. Distribution and power transformers serve utilities and factories, dry-type units serve buildings, and MCC, PCC and control panels serve plants. Because failure is costly and dangerous, test evidence matters more than the brochure. Because a transformer or panel can run for decades and a failure can stop a plant, the cheapest quotation is often the costliest choice. Compare losses, test evidence, the make of critical components and the supplier’s service record, and make sure the specification matches the standard your electricity utility or consultant requires.

How to choose

  1. Define the electrical duty: rating, primary and secondary voltage, phases, frequency, impedance and tap range.
  2. Choose oil-filled or dry-type by location, fire-safety needs and maintenance capability.
  3. Ask for the applicable Indian or international standard the product is built and tested to.
  4. Request type-test and routine-test reports, ideally from an accredited laboratory, and ask which tests are done on every unit.
  5. Compare losses and efficiency, which affect running cost for the life of the transformer.
  6. For panels, check the busbar rating, short-circuit rating, enclosure protection and the make of breakers and relays.
  7. Confirm warranty terms, spares and service response.
  8. Check transport and installation: weight, dimensions, oil handling and commissioning tests, and agree who is responsible for each before the unit leaves the factory.

Specifications to confirm with the supplier

SpecificationWhat to ask
Rating and voltagekVA or MVA rating, voltage ratio, phases and frequency.
Standard and testsThe standard followed and the type and routine test reports.
Losses and efficiencyNo-load and load losses at rated conditions.
Cooling and insulationOil-immersed or dry-type, temperature-rise class and insulation material.
Short-circuit withstandDesign capability and test evidence.
Panel componentsBreaker, relay and meter makes and the busbar rating.
WarrantyDuration, what it covers and who attends faults on site.

Where it is used

Frequently asked questions

What is the difference between type tests and routine tests?

Type tests prove a design on a representative unit; routine tests are carried out on each unit before dispatch. Ask for both.

Why do transformer losses matter?

A transformer is energised for years, so even a small difference in losses adds up to a significant cost over its life.

Dry-type or oil-filled?

Dry-type units avoid oil and suit indoor and fire-sensitive locations; oil-filled units are common for outdoor and higher ratings.

What documents should come with a transformer?

Test certificates for the unit, the rating plate details, drawings, an operation and maintenance manual and the warranty terms.

Should I inspect a transformer before dispatch?

If the order is large or critical, arrange a factory inspection and witness the routine tests, or appoint an independent inspector to do so.